CENTRAL AMERICA
|
|
|
|
|
|
G-3C at 95 W |
|
|
|
|
- C-band North America Beam
- Ku-band North America & Puerto Rico Beam
- Ku-band North America Beam
Key Parameters |
Total Transponders |
C-Band: Ku-Band: |
24 x 36 MHz 16 x 27 MHz, 8 x 54 MHz |
Polarization |
C-Band: Ku-Band: |
Linear - Horizontal or Vertical Linear - Horizontal or Vertical |
Downlink Frequency |
C-Band: Ku-Band: |
3700 to 4200 MHz 11.70 to 12.20 GHz |
Typical Edge of Coverage e.i.r.p. |
C-Band: Ku-Band: North America: North America & Puerto Rico: |
>39.0 dBW >47.0 dBW >45.0 dBW |
Uplink Frequency |
C-Band: Ku-Band: |
5925 to 6425 MHz 14.00 to 14.50 GHz |
Typical Edge of Coverage G/T |
C-Band: Ku-Band: North America: North America & Puerto Rico: |
>0.0 dB/K >2.0 dB/K >0.0 dB/K |
SFD Range (0.0 G/T and dB attn) |
C-Band: Ku-Band: |
-97.0 dBW/m -101.0 dBW/m |
|
G-11 at 91 W |
|
|
|
|
- C-band North America Beam
- Ku-band North America Beam
Key Parameters |
Total Transponders |
C-Band: Ku-Band: |
24 x 36 MHz 24 x 36 MHz |
Polarization |
C-Band: Ku-Band: |
Linear - Horizontal or Vertical Linear - Horizontal or Vertical |
Downlink Frequency |
C-Band: Ku-Band: |
3700 to 4200 MHz 11.75 to 12.20 GHz |
Typical e.i.r.p. |
C-Band CONUS: North America: Hawaii: Ku-Band CONUS: North America: |
>38.0 dBW >37.0 dBW >31.0 dBW >47.0 dBW (H), >45.5 dBW (V) >45.0 dBW |
Uplink Frequency |
C-Band: Ku-Band: |
5925 to 6425 MHz 14.00 to 14.50 GHz |
Typical G/T |
C-Band CONUS: North America: Hawaii: Ku-Band CONUS: North America: |
>1.0 dB/K (Horiz.), >2.0 dB/K (Vert.) >-2.0 dB/K (Horiz.), >0.0 dB/K (Vert.) >10.0 dB/K (Horiz.), >6.0 dB/K (Vert.) >4.0 dB/K >0.0 dB/K (Horiz.), >0.0 dB/K (Vert.) |
SFD Range (0.0 dB/K and 0 dB attn) |
C-Band: Ku-Band: |
-91.0 dBW/m (Horiz.), -91.0 dBW/m (Vert.) -93.5 dBW/m |
|
G-13 at 127 W |
|
|
|
|
- C-band North America Beam
Key Parameters |
Total Transponders |
|
24 x 36 MHz |
Polarization |
|
Linear - Horizontal or Vertical |
Downlink Frequency |
|
3700 to 4200 MHz |
Typical Edge of Coverage e.i.r.p. |
|
>40.0 dBW |
Uplink Frequency |
|
5925 to 6425 MHz |
Typical Edge of Coverage G/T |
|
>-10.0 dB/K |
SFD Range (0.0 dB/K and 0 dB attn) |
|
G-14 at 125 W |
|
|
|
|
- C-band North America Beam
Key Parameters |
Total Transponders |
|
24 x 36 MHz |
Polarization |
|
Linear - Horizontal or Vertical |
Downlink Frequency |
|
3700 to 4200 MHz |
Typical e.i.r.p. |
North America: Alaska: Caribbean: Hawaii: |
>40.0 dBW >39.0 dBW >36.0 dBW >36.0 dBW |
Uplink Frequency |
|
5925 to 6425 MHz |
Typical Edge of Coverage G/T |
|
>0 dB/K |
SFD (0.0 dB/K and 0 dB attn) |
|
-113.0 dBW/m |
|
G-15 at 133 W |
|
|
|
|
- C-band North America Beam
Key Parameters |
Total Transponders |
|
24 x 36 MHz |
Polarization |
|
Linear - Horizontal or Vertical |
Downlink Frequency |
|
3700 to 4200 MHz |
Typical e.i.r.p. |
North America: Alaska: Caribbean: Hawaii: |
41.0 dBW 39.0 dBW 36.0 dBW 36.0 dBW |
Uplink Frequency |
|
5925 to 6425 MHz |
Typical G/T |
|
-6.0 dB/K |
SFD (0.0 dB/K and 0 dB attn) |
|
-113.0 dBW/m |
|
G-16 at 99 W |
|
|
|
|
- C-band North America Beam
- Ku-band North America Beam
Key Parameters |
Total Transponders |
C-Band: Ku-Band: |
24 x 36 MHz 24 x 36 MHz |
Polarization |
C-Band: Ku-Band: |
Linear - Horizontal or Vertical Linear - Horizontal or Vertical |
Downlink Frequency |
C-Band: Ku-Band: |
3700 to 4200 MHz 11.70 to 12.20 GHz |
Typical Edge of Coverage e.i.r.p. |
C-Band: Ku-Band: |
>41.0 dBW >46.0 dBW |
Uplink Frequency |
C-Band: Ku-Band: |
5925 to 6425 MHz 14.00 to 14.50 GHz |
Typical Edge of Coverage G/T |
C-Band: Ku-Band: |
>1.0 dB/K >0.0 dB/K |
SFD (0.0 dB/K and 0 dB attn) |
C-Band: Ku-Band: |
-104.0 dBW/m -98.0 dBW/m |
|
|
|
|
top back |
|
|
|
|